Evaluation of Efficiency of SPR-Based Biosensor and ZnO Photoluminescent Biosensor ib the Anlysys of Biogenic Polyamines

dc.contributor.authorPrylutskyi, Maksym
dc.contributor.authorStarodub, Nickolaj
dc.contributor.authorTaran, O.
dc.date.accessioned2022-01-29T23:09:29Z
dc.date.available2022-01-29T23:09:29Z
dc.date.issued2020
dc.description.abstractIn this research it was demonstrated the efficiency of the biosensors based on the different principles at the detection of the biogenic amines which are as informative elements at the diagnostic of the cancer events including development of the breast cancer. It was compared two type of the optical devices namely based on the surface plasmon resonance (SPR) and on the photoluminescence of the ZnO nanostructures. Both types of the biosensors could able to detect such low molecular agents as polyamines in model solution at the concentration from 10 to 100 ng/ml. Nevertheless SPR-based biosensor showed better results than ZnO biosensor at the detecting as low and high concentrations of polyamines. In particular, the differences in the analyse efficiency at the determination of the above indicated concentrations between the used biosensors was in range from 14% to 30%. In spite of this data it was demonstrated that ZnO biosensor also may be used for estimation of level of polyamines at the cancer diagnostics.uk_UA
dc.identifier.citationPrilutskiy M. P. Evaluation of Efficiency of SPR-Based Biosensor and ZnO Photoluminescent Biosensor ib the Anlysys of Biogenic Polyamines / M. P. Prilutskiy, N. F. Starodub and O. P. Taran // World Journal of Engineering Research and Technology. - 2020. - Vol. 6, Issue 6. - P. 230-237.uk_UA
dc.identifier.urihttps://ekmair.ukma.edu.ua/handle/123456789/22488
dc.language.isoenuk_UA
dc.relation.sourceWorld Journal of Engineering Research and Technology.uk_UA
dc.statusfirst publisheduk_UA
dc.subjectBiosensorsuk_UA
dc.subjectSPRuk_UA
dc.subjectzinc oxideuk_UA
dc.subjectphotoluminescenceuk_UA
dc.subjectpolyaminesuk_UA
dc.subjectarticleuk_UA
dc.titleEvaluation of Efficiency of SPR-Based Biosensor and ZnO Photoluminescent Biosensor ib the Anlysys of Biogenic Polyaminesuk_UA
dc.typeArticleuk_UA
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Prilutskiy_Evaluation_of_Efficiency_of_SPR-Based_Biosensor.pdf
Size:
358.78 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
7.54 KB
Format:
Item-specific license agreed upon to submission
Description: